Sfp 1.25gbps 40km 1550nm

Features

  • Dual data-rate of 1.25Gbps operation 
  • 1310nm DFB laser and PIN photo detector for 40km transmission 
  • Compliant with SFP MSA and SFF-8472 with duplex LC receptacle 
  • Digital Diagnostic Monitoring: Internal Calibration or External Calibration 
  • Compatible with SONET OC-24-LR-1 
  • Compatible with RoHS 
  • 3.3V single power supply 

Operating case temperature:

  • Standard: 0 to 70°C
  • Industrial: -20 to 85°C 

 

Applications

  • Gigabit Ethernet 
  • Fiber Channel 
  • Switch to Switch interface 
  • Switched backplane applications 
  • Router/Server interface 
  • Other optical transmission systems

Description
The SFP transceivers are high performance, cost effective modules supporting dual data-rate of 1.25Gbps and 40km transmission distance with SMF.
The transceiver consists of three sections: a DFB laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. 
For further information, please refer to SFP MSA.

Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage Vcc -0.5 4.5 V
Storage Temperature Ts -40 85 °C
Operating Humidity 5 85 %

Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature Standard Tc 0 70 °C
Industrial -20 85 °C
Power Supply Voltage Vcc 3.13 3.3 3.47 V
Power Supply Current Icc 300 mA
Data Rate 1.25 Gbps

Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter
Centre Wavelength λc 1260 1310 1360 nm
Spectral Width (-20dB) ∆λ 1 nm
Side Mode Suppression Ratio SMSR 30 dB
Average Output Power Pout -9 -3 dBm 1
Extinction Ratio ER 9 dB
Optical Rise/Fall Time(20%~80%) tr/tf 0.26 ns
Data Input Swing Differential VIN 400 1800 mV 2
Input Differential Impedance ZIN 90 100 110 Ω
TX Disable Disable 2.0 Vcc V
Enable 0 0.8 V
TX Fault Fault 2.0 Vcc V
Normal 0 0.8 V
Receiver
Centre Wavelength λc 1260 1580 nm
Receiver Sensitivity -23 dBm 3
Receiver Overload -3 dBm 3
LOS De-Assert LOSD -24 dBm
LOS Assert LOSA -30 dBm
LOS Hysteresis 1 4 dB
Data Output Swing Differential Vout 400 1800 mV 4
LOS High 2.0 Vcc V
Low 0.8 V

Notes:
1. The optical power is launched into SMF.
2. PECL input, internally AC-coupled and terminated.
3. Measured with a PRBS 27-1 test pattern @1250Mbps, BER ≤1×10-12.
4. Internally AC-coupled.

Recommended Interface Circuit

Mechanical Dimensions

Digital Diagnostic Memory Map

The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA).

The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring.

The digital diagnostic memory map specific data field defines as following.

comercial@altistelecom.com.br